Multi-axis controllers Rated data Overview 5 5.3 5.3.1 5.3 Rated data The E94A M xExxx 4 devices can be used in the voltage range of 260 ... 775 V DC. Note! To ensure a faultless operation of the devices the code C00173 must be set according to the mains voltage connected. 5.3.1 Overview Input data c Temperature in the control cabinet Output data c Temperature in the control cabinet 1) The output frequency is limited to 1/8 of the selected chopper frequency (see C00018). 5.3-1 EDS94SPP101 EN 3.1-04/2007 Voltage Frequency Current [A] Number of phases Type [V] [Hz] max. +45 °C c max.
+55 °C c E94AMxE0024 325/565/705 0 ( DC) 2.6/2.6/2.3 2.0/2.0/1.7 2 E94AMxE0034 325/565/705 0 ( DC) 4.3/4.3/3.8 3.2/3.2/2.9 2 E94AMxE0044 325/565/705 0 ( DC) 6.7/6.7/5.9 5.0/5.0/4.4 2 E94AMxE0074 325/565/705 0 ( DC) 12.1/12.1/10.6 9.1/9.1/8.0 2 E94AMxE0094 325/565/705 0 ( DC) 15.4/15.4/13.5 11.6/11.6/10.1 2 E94AMxE0134 325/565/705 0 ( DC) 20.6/20.6/18.0 15.5/15.5/13.5 2 E94AMxE0174 325/565/705 0 ( DC) 25.7/25.7/22.5 19.3/19.3/16.9 2 E94AMxE0244 325/565/705 0 ( DC) 35.5/35.5/31.1 26.3/26.3/23.3 2 Voltage Frequency 1) Current [A] Number of phases Type [V] [Hz] max. +45 °C c max.
+55 °C c E94AMxE0024 0 - 230/400/500 0 - 599 1.5/1.5/1.3 1.1/1.1/1.0 3 E94AMxE0034 0 - 230/400/500 0 - 599 2.5/2.5/2.2 1.9/1.9/1.7 3 E94AMxE0044 0 - 230/400/500 0 - 599 4/4/3.5 3/3/2.6 3 E94AMxE0074 0 - 230/400/500 0 - 599 7/7/6.1 5.3/5.3/4.6 3 E94AMxE0094 0 - 230/400/500 0 - 599 9.3/9.3/8.2 7.0/7.0/6.2 3 E94AMxE0134 0 - 230/400/500 0 - 599 13/13/11.4 9.8/9.8/8.6 3 E94AMxE0174 0 - 230/400/500 0 - 599 16.5/16.5/14.4 12.4/12.4/10.8 3 E94AMxE0244 0 - 230/400/500 0 - 599 23.5/23.5/20.6 17.6/17.6/15.5 3 Power loss PV [W] Type when operating with rated output current IaN when controller is inhibited E94AMxE0024 100 40 E94AMxE0034 120 E94AMxE0044 150 E94AMxE0074 190 E94AMxE0094 230 E94AMxE0134 280 E94AMxE0174 320 E94AMxE0244 420