Lenze — 6.3.1 Operation at rated mains voltage 230 V

DC power supply modules Rated data (devices for 400/500V mains) Operation at rated mains voltage 230 V 6 6.3 6.3.1 Output data c Temperature in the control cabinet 100 % Permanent rated values Cycle 1 Cycle for the second-range (0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value) Cycle 2 Cycle for the minute-range (60 s overload/120 s recovery time with 75 % of the permanent rated value)  6.3-3 EDS94SPP101 EN 3.1-04/2007 Basis of the data Mains Rated voltage UDC [V] Voltage range UDC [V] Frequency range [Hz] 325 260 - 0 % ... 370 + 0 % Voltage Frequency Current [A] Number of phases Type [V] [Hz] max. +45 °C c max.

+55 °C c 325 0 (DC) 10 7.5 325 0 (DC) 36 27 325 0 (DC) 100 75 325 0 (DC) 245 184 Output current and output power 100 % Cycle 1 Cycle 2 Type IDC [A] PDC [kW] IDC [A] PDC [kW] IDC [A] PDC [kW] E94APNE0104 10 2.1 40 8.4 15 3.2 E94APNE0104 + E94AZMP0084 10 2.8 40 11.2 15 4.2 E94APNE0364 36 7.5 108 22.5 54 11.3 E94APNE0364 + E94AZMP0294 36 10.1 108 30.3 54 15.5 E94APNE1004 100 20.8 200 62.4 150 31.2 E94APNE1004 + E94AZMP0824 100 27.9 200 83.7 150 41.9 E94APNE2454 245 51 368 153 368 76.5 E94APNE2454 + E94AZMP2004 245 68.5 368 206 368 103