Lenze — 4.3.1 Overview

Single-axis controllers Rated data (devices for 400/500V mains) Overview 4 4.3 4.3.1 4.3 Rated data (devices for 400/500V mains) The E94ASxExxx 4 devices can be used in the voltage range of 180 V ... 550 V AC.  Note! To ensure a faultless operation of the devices the code C00173 must be set according to the mains voltage connected. 4.3.1 Overview Input data c Temperature in the control cabinet  4.3-1 EDS94SPP101 EN 3.1-04/2007 Voltage Frequency Current [A] Number of phases Type [V] [Hz] max. +45 °C c max.

+55 °C c E94ASxE0024 230/400/500 50/60 2.1/2.1/1.8 1.6/1.6/1.4 3 E94ASxE0034 230/400/500 50/60 3.5/3.5/3.1 2.6/2.6/2.3 3 E94ASxE0044 230/400/500 50/60 5.5/5.5/4.8 4.1/4.1/3.6 3 E94ASxE0074 230/400/500 50/60 9.9/9.9/8.6 7.4/7.4/6.5 3 E94ASxE0134 230/400/500 50/60 16.8/16.8/14.7 12.6/12.6/11.0 3 E94ASxE0174 230/400/500 50/60 21/21/18.3 15.8/15.8/13.8 3 E94ASxE0244 230/400/500 50/60 29/29/25.4 21.8/21.8/19.1 3 E94ASxE0324 230/400/500 50/60 29/29/26 22/22/20 3 E94ASxE0474 230/400/500 50/60 43/43/39 32/32/29 3 E94ASxE0594 230/400/500 50/60 47/47/41 35/35/31 3 E94ASxE0864 230/400/500 50/60 79/79/70 59/59/52 3 E94ASxE1044 230/400/500 50/60 95/95/84 71/71/63 3 E94ASxE1454 400/500 50/60 140/140 126/126 3 E94ASxE1724 400/500 50/60 166/166 149/149 3 E94ASxE2024 400/500 50/60 195/195 176/176 3 E94ASxE2454 400/500 50/60 237/237 213/213 3 E94ASxE2924 400/500 50/60 280/280 252/252 3 E94ASxE3664 400/500 50/60 354/354 319/319 3 E94ASxE4604 400/500 50/60 444/444 400/400 3 E94ASxE5724 400/500 50/60 553/553 498/498 3 E94ASxE6354 400/500 50/60 614/614 553/553 3 E94ASxE6954 400/500 50/60 672/672 605/605 3