4 4.5 4.5.2 Single-axis controllers Mechanical installation Devices in the range 2 ... 24 A (0.37 ... 11 kW) Mounting grid We recommend to provide the mounting plate with a grid pattern of M5 threaded holes for attaching the devices. This preparation enables easy attachment of the devices and the device sizes 1, 2, ... n can thus be mounted directly adjacent to each other. Note! ƒ M5 screw and washer assemblies or hexagon socket screws with washers are permitted. ƒ Tightening torque: 3.4 Nm / 30 lb-in. ƒ In the installation backplane, the screwed connection may not jut out more than 7 mm. 9400SSP0010 Fig. 4.5-1 Mounting grid for installation backplane and filter of device sizes 1 ...
3 Installation backplane without footprint filter (mains or RFI filter) Installation backplane with footprint filter Grid hole pattern for installation backplane (M5 threaded holes) Grid hole pattern for footprint filter (M5 threaded holes) Cable duct 1 ... 3 Device size, mounting holes used 4.5-2 EDS94SPP101 EN 3.1-04/2007