Single-axis controllers Wiring Devices in the range 2 ... 24 A (0.37 ... 11 kW) 4 4.6 4.6.3 External brake resistor Motor 4.6-11 EDS94SPP101 EN 3.1-04/2007 Terminal X105 (left part) Labelling Description Rb1 Rb2 Terminal da ta Max. conductor cross-section [mm2] [AWG] Tightening torque Screw drive [AWG] [Nm] [lb-in] Device sizes flexible with wire e ferrule 1+2: 2.5 nd 12 0.5 ... 0.6 4.5 ... 6.2 PZ0 Device size flexible with wire e ferrule 3: 10 nd 6 1.2 ... 1.5 10.6 ...
13.3 PZ1 Terminal X105 (right part) Labelling Description SSP940X105 U V W Connection of the motor phases Functional earth Connect the shields of the motor phases and of the optional motor brake control separately and with a surface as large as possible to the shield sheet. Use EMC wire clamp or EMC shield clamp for fixing. Connection for the PE conductor on the motor side with M5 ring cable lug Terminal da ta Max. conductor cross-section [mm2] [AWG] Tightening torque Screw drive [AWG] [Nm] [lb-in] Device sizes flexible with wire e ferrule 1+2: 2.5 nd 12 0.5 ... 0.6 4.5 ... 6.2 PZ0 Device size flexible with wire e ferrule 3: 10 nd 6 1.2 ... 1.5 10.6 ... 13.3 PZ1