User Manual of A90 Series Inverter 107 F15.34 Fan control 0: running after power-on 1: running at startup 2: intelligent operation, subject to temperature control 2 ○ F15.35 Overmodulation intensity 1.00 - 1.10 1.05 ● F15.39 Terminal jog priority 0: Invalid 1: valid 0 ○ F15.40 Deceleration time for quick stop 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 1.00 ● F15.68 Energy price 0.00 - 100.0 1.00 ● F15.69 Power-frequency load factor 30.0-200.0 % 90 ○ F16 Customization function group F16.00 Industry application 0: general model 1: air compressor application 2: extruder application 3: water pump application 4:

fan application 0 ○ F16.01 Set length 1 - 65535 (F16.13=0) 0.1 - 6553.5 (F16.13=1) 0.01 - 655.35 (F16.13=2) 0.001 - 65.535 (F16.13=3) m 1,000 ● F16.02 Pulses per meter 0.1 - 6553.5 100.0 ● F16.03 Set count value F16.04 - 65535 1,000 ● F16.04 Specified count value 1 - F16.03 1,000 ● F16.05 Set time of regular running 0.0-6500.0; 0.0: invalid min 0.0 ● F16.06 Agent password 0 - 65535 0 ● F16.07 Setting of cumulative power-on arrival time 0-65535; 0: disable the protection when the power-on time is up h 0 ● F16.10 Setting of cumulative running arrival time 0-65535; 0:

disable the protection when the running time is up h 0 ● F16.09 Factory password 0 - 65535 XXXX X ● F16.10 Analog output percentage corresponding to the count value 0 0.00-100.00 % 0.00 ○ F16.11 Analog output 0.00-100.00 % 100.00 ○