sinee — Руководство по эксплуатации Inverter A90 от SINEE (EN)

User Manual of A90 Series Inverter 12 Input frequency Digital input: 0.01Hz/0.1Hz resolution Analog input: 0.1% of maximum frequency Speed control 1:50 (VVF), 1:200 (SVC) range Speed control Rated synchronous speed ± 0.2% accuracy Acceleration and 0.01s to 600.00s / 0.1s to 6,000.0s / 1s to 60,000s deceleration time Voltage/frequency Rated output voltage: 20% to 100%, adjustable characteristics Reference frequency: 1Hz to 600Hz/3,000Hz Fixed torque boost curve Torque boost Any V/F curve is acceptable.

150%/1Hz (VVF) Starting torque 150%/0.25Hz (SVC) Torque control ±8% rated torque (SVC) accuracy Self-adjustment of When the input voltage changes, the output voltage will output voltage basically remain unchanged. Automatic current Output current is automatically limited to avoid frequent limit overcurrent trips. Braking frequency: 0.01 to maximum frequency DC braking Braking time: 0 - 30S Braking current: 0% to 150% rated current Signal input Communication, multi-speed, analog, etc. source Reference power 10V/20mA Input and supply output Terminal control 24V/100mA function power Digital input 51)-channel digital multi-function input: