sinee — Руководство по эксплуатации Inverter A90 от SINEE (EN)

User Manual of A90 Series Inverter Set the acceleration and deceleration time during rapid stop. 7.17 Virtual I/O Function Parameter Group of F17 Group terminals (VX1 to VX8), of which the functions and usages are basically the same as those The standard A90 series inverter is equipped with eight virtual multi-function input of the actual input terminals. Differences are described below. For their similarities, refer to the parameter description of the digital input terminal function options of the F02 group.

241 Parameter description Default Function code Function code name Unit Attribute setting F15.40 Deceleration time for quick stop 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 1.00 ● Function Default Function code name Parameter description Unit Attribute code setting F17.00 VX1 virtual input function options The same as the digital input terminal function options of the F02 group. See the function list of the digital multi-function input terminal in Table 7-2.

0 ○ F17.01 VX2 virtual input function options 0 ○ F17.02 VX3 virtual input function options 0 ○ F17.03 VX4 virtual input function options 0 ○ F17.04 VX5 virtual input function options 0 ○ F17.05 VX6 virtual input function options 0 ○ F17.06 VX7 virtual input function options 0 ○ F17.07 VX8 virtual input function options 0 ○ F17.08 Virtual input positive/negative logic * * D5 D4 D3 D2 D1 D0 000 00000 ○ VX 8 VX 7 VX 6 VX 5 VX 4 VX 3 VX 2 VX 1 0: positive logic, valid in the closed state/invalid in the open state 1: Negative logic, invalid in the