User Manual of A90 Series Inverter F00.02=0: keyboard control The inverter start and stop are controlled by the RUN, STOP and multi-function keys M.K on the keyboard. In the case of no fault, press the multi-function key M.K to enter the jog running status, and the RUN key to enter the running status. If the green LED indicator above the RUN key is normally ON, it indicates that the inverter is running. If this indicator is flickering, it indicates that the inverter is in the status of deceleration to stop. F00.02=1: terminal control The inverter start and stop are controlled by the start and stop control terminals defined by the function code F02.00 to F02.05.
Terminal control is dependent on F00.03. F00.02=2: communication control The inverter start and stop are controlled by the host through the RS485 communication port. F04.00=0: direct start The inverter will be started at the starting frequency, following DC braking (no DC braking in the case of F04.04=0) and pre-excitation (no pre-excitation if F04.07 is set to 0). After the starting frequency duration expires, the inverter will run at the set frequency. F04.00=1: start with speed tracking The inverter is smoothly started at the current rotating frequency of the motor, following the speed tracking. F04.19=0:
deceleration to stop The motor decelerates to stop according to the set deceleration time [default setting: based on F00.15 (deceleration time 1)]. F04.19=1: free stop When there is a valid stop command, the inverter will stop output immediately, and the motor will freely coast to stop. The stop time depends on the inertia of the motor and load. 57 Function Function code name Default Parameter description Attribute code setting F00.02 s 0 Command 1 ource selection 2 : keyboard control : Terminal control : Communication control 0 ○ Function Function code Default Parameter description Attribute code name setting F04.00 Start-up method 0: direct start 1:
start of speed tracking 0 ○ Function Function code Parameter description Default Attribute code name setting F04.19 Stop mode 0: Slow down to stop 1: Free stop 0 ○