sinee — Руководство по эксплуатации Inverter A90 от SINEE (EN)

User Manual of A90 Series Inverter 68 2: valid 2 F00.25 Noise suppression of carrier frequency 0: Invalid 1: valid 0 ○ F00.26 Noise suppression tone 20~200 Hz 40 ● F00.27 Noise suppression intensity 10~150 Hz 0 ● F00.28 Options of motor parameter group 0: parameter group of motor 1 1: parameter group of motor 2 0 ○ F00.29 User password 0~65,535 0 ○ F00.30 Inverter type 0: heavy-duty 1: light-duty 0 ○ F01 Parameter group of motor 1 F01.00 Motor type 0: ordinary asynchronous motor 1: variable-frequency asynchronous motor 2:

permanent magnet synchronous motor 0 ○ F01.01 Rated power of electric motor 0.10~650.00 kW Model Confirm ○ F01.02 Rated voltage of motor 50~2,000 V Model Confirm ○ F01.03 Rated current of motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.1 to 6,000.0 (rated power of motor: > 75 kW) A Model Confirm ○ F01.04 Rated frequency of motor 0.01~600.00 Hz Model Confirm ○ F01.05 Rated speed 1~60,000 rpm Model Confirm ○ F01.06 Motor winding connection 0: Y 1: Δ Model Confirm ○ F01.07 Rated power factor of motor 0.600~1.000 Model Confirm ○ F01.08 Motor efficiency 30.0~100.0 % Model Confirm ○ F01.09 Stator resistance of asynchronous motor 1-60,000 (rated power of motor:

≤ 75 kW) 0.1-6,000.0 (rated power of motor: > 75kW) mΩ Model Confirm ○ F01.10 Rotor resistance of asynchronous motor 1-60,000 (rated power of motor: ≤ 75 kW) mΩ Model Confirm ○