User Manual of A90 Series Inverter 87 F08.16 Limited number of cycles 1~10,000 1 ● F08.17 Simple PLC memory options Ones place: Stop memory options 0: no memory (from the first segment) 1: memory (from the moment of stop) Tens place: Power-down memory options 0: no memory (from the first segment) 1: Memory (from the power-down moment) 0 ● F08.18 Simple PLC time unit 0: s (second) 1: min (minute) 0 ● F08.19 Setting of the first segment Ones place: Running direction options 0: forward 1: reverse Tens place: Acceleration and deceleration time options 0: acceleration and deceleration time 1 1: acceleration and deceleration time 2 2: acceleration and deceleration time 3 3:
acceleration and deceleration time 4 0 ● F08.20 Running time of the first segment 0.0 - 6000.0 s/ min 5.0 ● F08.21 Setting of the second segment Ones place: Running direction options 0: forward 1: reverse Tens place: Acceleration and deceleration time options 0: acceleration and deceleration time 1 1: acceleration and deceleration time 2 2: acceleration and deceleration time 3 0 ●