AC70E manual V1.3

FOREWORD Thank you for using AC70E series inverter produced. AC70E series inverter is a new generation of high-performance mini -frequency inverter independently developed,With advanced control method and rich function design. Users will be satisfied by the simplified PLC, PID adjustor, programming I/O terminal, RS485 interface, analog I/O terminal, and other specific control functions for particular industries in the benefit of AC70E This manual is the supporting data sheet for AC70E This instruction manual includes save tips, instructions (messages) of installing wiring, keyboard operation, simple function table, troubleshooting, maintenance only.

For parameters setting detail, pls read AC70 general used series manual or consult us. For the best results and safe operations with the AC70 series, carefully read and keep this manual. Make sure it is handy for the ultimate user of the inverters for reference. To receive technical support related to the inverter, please contact sales office or the dealer from whom you purchased. You can also contact our Customer Service Center, and we will try our best to help you. We are sparing no effort to upgrade our products and regret not to issue prior notification if there is any revision to this instruction manual. Pray for your consideration for the inconveniences 1

Стр. 2

AC70E manual V1.3

Chapter 1: Summarize 1.1 Safety requirements and cautions To ensure safety of your health, equipment and property, please read this chapter carefully before use the frequency inverter and act in compliance with the instructions while carrying, installing, debugging, running and overhauling the frequency inverter. Warn sign and meaning Qualified operation Only qualified person after professional train can operate the equipment.The operator must be with professional train, familiar with installation, wiring, running and maintain of equipment, and can deal emergency case.

Safe guide Warn sign is for safe, to prevent operator from hurt and prevent this product and relating equipment from being damaged. Before operating, be sure to carefully read the manual about safety, installation, operation and maintenance and obey to the safe rules and warn sign. Right transport, store, installation and careful operation and maintenance is most important for inverter safe run. In transport and store process, make sure the inverter is free from impact and vibration. It must be stored where is dry, without corrosive air and conductive dust, temperature lower than 60 . This product carries dangerous voltage and controls driver machine with potential danger.

If not abide the regulations or requirements in this manual, there is danger of body injury even death and machine system damage. Do not wire while the power is conneted. Otherwise there is danger of death for electric shock. Before wiring, inspection, maintenance, please cut power supply of all related equipments and ensure mains DC voltage in safe range. And please do operation after 5 mins. Power wire, motor wire and control wire should be all connected firmly. Earth must be reliable and earth resistance must be lower than 10Ω. Human body electrostatic will seriously damage inner sensitive components. Before operation, please follow ESD measures.

Otherwise there is danger of iverter damage. Inverter output voltage is pulse wave. If components such as capacitor what improves power factor and pressure-sensitive resistance for anti-thunder and so on are installed at the output side, please dismantle or change to input side. No switch components such as breaker and contactor at the output side. (If there must be one, please make sure the output current is 0 while the switch acting). No matter where the fault is, there is danger of serious accident, even human body injury what means dangerous malfunction possibility.

So there must be additional external prevent measures or other safety devices, such as independent current limiting switch, machinery fense and so on. Only used in application fields as maker stated. No use in equipments related to special fields such as emergency, succor, ship, medical treatment, avigation, nuclear and etc. Only service department of the maker or its authorized service center or professional person trained and authorized by Veich can maintain the products. They should be very familiar with the safety warning and operation gist in this manual. 2 Danger: it will cause danger of serious injuries and even death while operating against the rules Caution:

it will cause danger of light injuries or equipment destruction while operating against the rules

Стр. 3

AC70E manual V1.3

1.2 Before use Pls check whether any package damage while receiving the product you ordered. If the package is ok, pls open it and check the inverter. If damage caused in transport, it is not duty of Veich company. But please contact Veich or the transport company immediately. After checking the product, please also check if the model is the one you ordered. The model of the product is on the nameplate “MODEL” column. If any problem, please contact us freely. Nameplate position and content POWER MODEL MODEL :

AC70E-T3-004G POWER 4KW OUTPUT SER NO INPUT INPUT 3PH AC 380V 50/60Hz OUTPUT 3PH AC 8.5A 0-400Hz SER NO Model explaination 2R2 T AC70E 3 G Inverter series Power Motor AC70E series R40 0.40KW 1.5KW 1R5 R75 0.75KW 2R2 2.2KW 4KW 004 Motor Inverter type universal G 3 Motor voltage T 3-phase S single-phase Motor voltage 3 380V 2 220V Single phase 220V Three phase 380V Model Ratted Max motor current Model Max motor Ratted current AC70E-S2-R40G 0.4kW 2.5A AC70E-T3-R75G 0.75kW 2.3A AC70E-S2-R75G 0.75kW 4A AC70E-T3-1R5G 1.5kW 3.7A AC70E-S2-1R5G 1.5kW 7A AC70E-T3-2R2G 2.2kW 5A AC70E-S2-2R2G 2.2kW 10A AC70E-T3-3R7G 3.7kW 8.5A

Стр. 4

AC70E manual V1.3

1.3 Product technique specifications 4 Items Specifications Power Voltage/frequency Single phase 220V 50/60Hz Three phase380V 50/60Hz Allowable fluctuations voltage:±15%, frequency:±5% Control Frequency range 0-400Hz Frequency ACCuracy ±0.5% of max frequency Frequency setting 0.01Hz:Operating“up”and”down”keys on keyboard 0.2Hz:Potentiometers analog input resolution Voltage/frequency Voltage 50% -100% the rated voltage adjustable, Motor rated frequency 25-400Hz(2000Hz) adjustable characteristics Carrier frequency 1.0-15.0KHz/Random carrier modulation Torque upgrade 0--25.0% adjustable/auto torque upgrade/random V/F curve optional Maximum Capacity 150% for one minute, 180% for 2s, 200% instant jump.

ACC and DECtime 0.1-6500s Rated output voltage Take advantage of the power supply voltage compensation function, if motor rated voltage is 100%,the voltage can be set in the 50 -100% scope(the voltage output should not exceed the input voltage ) AVR adjust When the grid voltage fluctuates, changes in the output voltage is very small, remained constant V / F Automatic ACCording to the load conditions, automatic optimize the V / F curves to implement energy saving operation energy-saving operation Standard functions PID control, ACC and DECtime adjustable, ACC and DECmode variable, Carrier frequency adjustment, Torque upgrade, Current limiting, Speed tracking and restart, Frequency hopping, Frequency fluctuation limite control, Program running, Multi-steps speed, Pendulum frequency operation, RS485, Analog output, Pulse output frequency Brake Energy-consuming braking, DC braking Frequency setting input Keyboard number settings, keyboard potentiometers/ external terminal VS:

0~10V, the external terminal AS : 4-20mA, RS485 and signal composition and terminal options Signal Feedback input External terminal VS: 0~10V external terminal AS: 4-20mA, RS485 Input order signals Start, stop, positive and negative rotating , jog, multi-steps speed, free parking, reset, ACC and DECtime choice, frequency settings channels choice, external malfunctions alarm External output signal Relay output, the collector output, 0-10V output, 4-20mA output, the frequency pulse output Protection function Overvoltage, undervoltage, current limiting, over-current, overload, electric thermal relays, overheat, pressure stall, data protection

Стр. 5