omron — ConformityTolerance

ConformityTolerance ConformityTolerance VPARAMETER 556 Maximum local deviation between the expected model contours of an instance and the contours actually detected in the input image. It corresponds to the maximum distance by which a matched contour can deviate from either side of its expected position in the model. This property can only be set when UseDefaultConformityTolerance is set to False. Otherwise, it is read-only.

Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 556, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 556, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 556, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 556, index_id, object_id) Type Double Remarks This property can be set to any positive value if ConformityToleranceRangeEnabled is set to False. Type Double Range Minimum: MinimumConformityTolerance Maximum: MaximumConformityTolerance Parameters ACE Reference Guide, 18317-000 Rev A Page 157 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP