omron — Connectivity

Connectivity Connectivity VPARAMETER 5120 Defines a minimum number of connected edges required to generate a point hypothesis from a a specific found edge, which satisfies the search constraints. Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5120, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5120, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5120, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5120, index_id, object_id) Type Long Range Minimum: 1 Maximum: 20 Parameters ACE Reference Guide, 18317-000 Rev A Page 161 $ip IP address of the vision server. Applies to V+ syntax only.

Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5120: the value used to reference this property. index id _ N/A object id _ N/A