omron — Edge1PolarityMode

Edge1PolarityMode Edge1PolarityMode VPARAMETER 5211 Selection criterion for the first edge of the selected pair. The greyscale transition of the edge must respect the polarity set by this property. Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5211, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5211, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5211, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5211, index_id, object_id) Type Long Range Parameters ACE Reference Guide, 18317-000 Rev A Page 179 Value Polarity Mode Name Description 0 hsDarkToLight The greylevel value must go from dark to light when crossing an edge.

1 hsLightToDark The greylevel value must go from light to dark when crossing an edge. 2 hsEitherPolarity The change in greylevel value is not a criterion for locating an edge. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1.