FilterLuminanceTolerance FilterLuminanceTolerance VPARAMETER 5718 Value of the tolerance allowed for the Luminance value, defined by FilterLuminanceValue, for the selected filter. The FilterLuminanceTolerance value is distributed equally above and below the FilterLuminanceValue. For example, if FilterLuminanceValue = 200 and FilterLuminanceTolerance = 20, the filter will accept pixels within a range of luminance values = [190,200].
Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5718, filter_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5718, filter_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5718, filter_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5718, filter_id, object_id) Remarks When FilterLuminanceTolerance = 1, no tolerance (variation) in luminance is accepted. The filter will only accept pixels with a luminance value equal to FilterLuminanceValue. Type Long Range Minimum: 1 Maximum: 128 Parameters ACE Reference Guide, 18317-000 Rev A Page 236 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example:
192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1.