FilterSaturationTolerance FilterSaturationTolerance VPARAMETER 5717 Value of the tolerance allowed for the saturation value, defined by FilterSaturationValue, for the selected filter. The FilterSaturationTolerance value is distributed equally above and below the FilterSaturationValue. For example, if FilterSaturationValue = 200 and FilterSaturationTolerance = 20, the filter will accept pixels with a range of saturation values = [190,200].
Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5717, filter_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5717, filter_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5717, filter_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5717, filter_id, object_id) Remarks When FilterSaturationTolerance = 1, no tolerance (variation) in saturation is accepted. The filter will only accept pixels with a saturation value equal to FilterSaturationValue. Type Long Range Minimum: 1 Maximum: 128 Parameters ACE Reference Guide, 18317-000 Rev A Page 240 $ip IP address of the vision server. Applies to V+ syntax only.
Uses standard IP address format, for example: 192.168.1.120.