ActiveCalibration FlexibowlFeederFlipCount VPARAMETER 7005 The number of iterations used in the flip operation. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 7005, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 7005, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 7005, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 7005, index_id, object_id) Type Real variable. Range Minimum: 1 Maximum: Unbounded Parameters ACE Reference Guide, 18317-000 Rev A Page 250 sequence id _ Index associated with the feeder as defined in the feeder editor. tool id _ N/A ID 7005: the value used to reference this property.
index id _ N/A object id _ N/A $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.