MinimumClearPercentage MinimumClearPercentage VPARAMETER 559 When MinimumClearPercentageEnabled is set to True, MinimumClearPercentage sets the minimum percentage of the model bounding-box area that must be free of obstacles to consider an object instance as valid. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 559, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 559, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 559, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 559, index_id, object_id) Type Double Range Minimum: 0.1 or greater. Maximum:
100.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 378 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 559: the value used to reference this property. index id _ N/A object id _ N/A