omron — MinimumScaleFactor

MinimumScaleFactor MinimumScaleFactor VPARAMETER 512 Minimum scale factor allowed for an object instance to be recognized. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 512, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 512, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 512, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 512, index_id, object_id) Remarks This property is applicable only if the NominalScaleFactor property is set to False. Type Double Range Minimum: 0.1 Maximum: 10.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 386 $ip IP address of the vision server. Applies to V+ syntax only.

Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 512: the value used to reference this property. index id _ N/A object id _ N/A