omron — NominalRotationEnabled

NominalRotationEnabled NominalRotationEnabled VPARAMETER 514 Specifies whether the rotation of a recognized instance must fall within the range set by MinimumRotation and MaximumRotation or be equal to the nominal value set by the NominalRotation property. When NominalRotationEnabled is set to True, the nominal value is applied. Otherwise, the range is used.

Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 514, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 514, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 514, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 514, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 393 Value Description 1 Locator searches for instances that meet NominalRotation constraint 0 Locator searches for instances within range set by MinimumRotation and MaximumRotation. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.

sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1.