omron — NominalScaleFactorEnabled

NominalScaleFactorEnabled NominalScaleFactorEnabled VPARAMETER 510 Specifies whether the scale factor of a recognized instance must fall within the range set by MinimumScaleFactor and MinimumScaleFactor or be equal to the nominal value set by the NominalScaleFactor property. When NominalScaleFactorEnabled is set to True, the nominal value is applied. Otherwise, the range is used.

Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 510, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 510, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 510, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 510, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 396 Value Description 1 Locator searches for instances that meet NominalScaleFactor constraint. 0 Locator searches for instances within range set by MinimumScaleFactor and MaximumScaleFactor. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.

sequence id _ Index of the vision sequence. The first sequence is 1.