VPARAMETER program instruction VPARAMETER program instruction NOTE: This keyword can also be used to control the Adept AnyFeeder. For details, see the Adept AnyFeeder User's Guide , Rev B or later. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, parameter_id, index_id, object_id) = value V+ VPARAMETER (sequence_id, tool_id, parameter_id, index_id, object_id) $ip = value Description Sets the current value of a vision tool parameter. Parameters Details The following parameters are optional: sequence_id, tool_id , parameter_id , index_id , and object_id . These parameters are 1-based. If no value is provided for these parameters, they default to 1.
For V+ systems, the vision server is the PC on which the ACE Sight vision software is running. Example ACE Reference Guide, 18317-000 Rev A Page 39 sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. parameter id _ Identifier (ID) of the parameter. Refer to the ACE Sight Properties Quick Reference tables to find the ID for the required parameter. index id _ Reserved for internal use. Value is always 1. object id _ Some parameters require an object index to access specific values in an array. Please refer to the details for the individual parameter to understand the meaning and possible usage.
$ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.