omron — OutputLineEndPointY

OutputLineEndPointY OutputLineEndPointY VRESULT 1824 Y-coordinate of the end point of the specified line entity. This property is read-only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1824, index_id, frame_id ) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1824, index_id, frame_id ) Type Double Range Unbounded Parameters ACE Reference Guide, 18317-000 Rev A Page 411 sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1824: the value used to reference this property.

index id _ N/A frame id _ Index of the frame that contains the specified instance. Range: [1, ResultCount -1] $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.