PairCount PairCount VPARAMETER 1920 PairCount indicates the number of pairs that have been configured for the tool. This property is read-only. Syntax Micro V+ value = VPARAMETER (sequence_id, tool_id, 1920, index_id, object_id) V+ value = VPARAMETER ($ip, sequence_id, tool_id, 1920, index_id, object_id) Remarks If an edge pair is not found, results for that edge pair appear as zero. However, the PairCount property is not affected. To get the number of pairs found by the tool use the ResultCount property. Type Long Range Minimum: 0 Maximum: Unlimited Parameters ACE Reference Guide, 18317-000 Rev A Page 423 $ip IP address of the vision server. Applies to V+ syntax only.
Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1920: the value used to reference this property.