omron — SegmentationDynamicInside

SegmentationDynamicInside SegmentationDynamicInside VPARAMETER 5010 Indexed property used to access the Dynamic Inside Segmentation function. Four points are available, from left to right: Bottom Left, Top Left, Top Right and Bottom Right. Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5010, constraint_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5010, constraint_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5010, constraint_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5010, constraint_id, object_id) Type Long Range Minimum: 0.0 Maximum:

100.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 478 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5010: the value used to reference this property. constraint id _ Point index for the Dynamic Inside Segmentation. (hsSegmentationInsidePoint) 0: hsInsideBottomLeft point