SharpnessPeak SharpnessPeak VRESULT 2001 Maximum Sharpness value computed by the tool. This property is read-only. Syntax MicroV+ value = VPARAMETER (sequence_id, tool_id, 2001, index_id, object_id) V+ value = VPARAMETER ($ip, sequence_id, tool_id, 2001, index_id, object_id) Type Double Range Minimum: 0 Maximum: 1000 Parameters ACE Reference Guide, 18317-000 Rev A Page 496 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 2001: the value used to reference this property.
index id _ N/A object id _ N/A