omron — TimeoutEnabled

TimeoutEnabled TimeoutEnabled VPARAMETER 500 Specifies if the timeout period set by the Timeout property will be used to limit the search time. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 500, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 500, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 500, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 500, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 514 Value Description 1 Search time is limited by the Timeout property. 0 Search time is not limited. $ip IP address of the vision server. Applies to V+ syntax only.

Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 500: the value used to reference this property. index id _ N/A object id _ N/A