SAFETY PRECAUTIONS rn ill POWER SUPPLY The ACT Apricot utilizes an ASTEC AC9335 power supply module. Appendix D gives a full specification of the unit. The unit is of the switch-mode type, and very high voltages are present throughout. If it is envisaged that any kind of testing or servicing be carried out, with the top cover removed, the following precautions should be taken: 1. Use 1:1 isolation transformer in the line. 2. Service only in a "high-voltage" test area. 3. Incorporate an emergency off switch. 4. Disconnect all earths from test equipment. 5. Take every precaution to minimise shock hazard.

It is highly recommended that in the case of failure, this unit should be returned to the distributor for repair.