AH Motion Controller – Operation Manual _9 9-24 Error code Description CPU Status LED indicator status ERROR BUS FAULT 16#757E Incorrect PLC password Continue Keep Keep 16#8105 The contents of the program downloaded are incorrect. The program syntax is incorrect. Continue Keep Keep 16#8106 The contents of the program downloaded are incorrect. The length of the execution code exceeds the limit. Continue Keep Keep 16#8107 The contents of the program downloaded are incorrect. The length of the source code exceeds the limit. Continue Keep Keep 16#8230 The CPU parameter downloaded is incorrect. The IP address is illegal. Continue Blinking Keep 16#8231 The CPU parameter downloaded is incorrect.
The netmask address is illegal. Continue Blinking Keep 16#8232 The CPU parameter downloaded is incorrect. The gateway address is illegal. Continue Blinking Keep 16#8233 The CPU parameter downloaded is incorrect. The IP address filter is set incorrectly. Continue Blinking Keep 16#8235 The CPU parameter downloaded is incorrect. The static ARP table is set incorrectly. Continue Blinking Keep 16#8236 A CPU parameter downloaded is incorrect. The NTP client service is set incorrectly. Continue Keep Keep 16#8240 A CPU parameter downloaded is incorrect.
The data exchange by means of Ethernet is set incorrectly Continue Keep Keep 16#8242 Gcode Data ERROR Continue Blinking Keep 16#8243 ECAM Data ERROR Continue Blinking Keep 16#8244 ENI Data ERROR Continue Blinking Keep 16#8245 EtherCat Data ERROR Continue Blinking Keep 16#8246 Axes Parameters Data ERROR Continue Blinking Keep 16#8247 External Gcode Data ERROR Continue Blinking Keep 16#8522 A module configuration is being scanned. Continue Keep Keep 16#853B An I/O module is not configured.(wirte error) Continue Keep Keep 16#853C An I/O module does not exist. (wirte error) Continue Keep Keep 16#854B An I/O module is not configured.
(read error) Continue Keep Keep 16#854C An I/O module does not exist. (read error) Continue Keep Keep 16#8572 The checksum of the module configuration table is incorrect. Continue Keep Keep 16#8576 The checksum of the module parameter setting is incorrect. Continue Keep Keep 16#857A The checksum of the module parameter mapping table is incorrect. Continue Keep Keep 16#85E1 An I/O interrupt number is incorrect. Continue Keep Keep 16#85E2 An I/O interrupt service routine does not exist. Continue Keep Keep 16#860F System restoration error Continue Keep Keep 16#8611 No memory card exists, or the memory card format is incorrect. Continue Keep Keep