Kaiyi — 11.4.2.2 AHRTU-DNET-5A Configuration Interface

Chapter 11 DeviceNet Remote I/O Module AHRTU-DNET 4. Click the right-side “Scan” button on the following “AHRTU-DNET-5A Configuration” interface. The abnormal icons may appear after scanning the I/O modules connected to AHRTU-DNET-5A is completed. The explanation of the abnormal icons is listed in the following table. 11-25 Item Description Output The output data mapping range of each module which depends on the start address offset and length of output mapping data Comment Remark for the I/O modules on the rack OK Click “OK” to exit from AHRTU-DNET-5A configuration interface and then the current configuration will be stored.

Cancel Click “Cancel” to exit from AHRTU-DNET-5A configuration interface but the current configuration will not be stored. The I/O module configured in the software does not match that actually connected. For example, the I/O module inserted to slot 4 in the rack 1 in the software is 32AM. But actually, it is 16AP connected. After scanning, the icon as left one is shown. Double click the icon and change it into the current configuration icon. The I/O module configured in the software does not match that actually connected by scanning. For example, the I/O module inserted to slot 4 in the rack 1 in the software is AH04AD-5A. But actually, no such a module is connected.

After scanning, the icon as left one is shown. Double click the icon and change it into the current configuration icon.