Delta AH500 — 6.3.2 Explanation of Data Conversion Instructions

Chapter 6 Applied Instructions 8. Take the 32-bit instruction for example. b31 b0 S . . .. . . . . . . .. . . . . . . .. . . . . 0 b0 b31 D D+1 D+2 . . . . . . . . . . . . . . . . . . D+29 D+30 D+31 Example: Suppose the value in D30 is 3. When M0 is ON, the values of the bits in D20 are stored in the third bits in D0~D15 in order. Additional remark: 1. If the device D+15 used in the 16-bit instruction exceeds the range, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003. 2. If the device D+31 used in the 32-bit instruction exceeds the range, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003. 3.

If n exceeds the range, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200B. 6-111 0 1 0 1 0 1 1 0 1 0 1 0