Delta AH500 — 6.14.2 Explanation of Structure Creation Instructions

Chapter 6 Applied Instructions Additional remark: 1. If the part of the program specified by the pointer in the instruction BREAK does not exist, the operation error occurs, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2004. 2. If the instruction BREAK is outside the FOR/NEXT loop, the operation error occurs, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2017. 3. Please refer to ISPSoft User Manual for more information related to the usage of the label. 6-315