Delta AH500 — 6.23.2 Explanation of Memory Card Instructions

AH500 Programming Manual Symbol: C : Control parameter Word S : File name Word S 1 : Data address in the file Double word S 2 : Reserved Word S 3 : Data length Double word D : Data destination Word Explanation: 1. The description of the operands:  C : The control parameter 6-532 API Instruction code Operand Function 2301 MREAD P C, S, S , S , S , D 1 2 3 Reading the data from the memory card into the PLC Device X Y M S T C HC D L SM SR E PR K 16# “$” DF C      S    S 1      S 2      S 3      D    Pulse instruction 16-bit instruction (13 steps) 32-bit instruction AH500 AH500 - Item Code Description File format 0 Binary value The default value is 0.

The file name extension is .dmd. The unit of the value is the word. 1 The values are separated by a comma. The unit of the value is the word. The file name extension is .cvs. The ASCII codes are adopted. The value which is stored is a hexadecimal value. 2 The values are separated by a comma. The unit of the value is the double word. The file name extension is .cvs. The ASCII codes are adopted. The value which is stored is a hexadecimal value. 3 The values are separated by a tab.