Delta AH500 — 6.25.2 Explanation of Task Control Instructions

AH500 Programming Manual begin to execute from STEP 1. When S 2 is set to 1, the status and the parameters will be cleared and will begin to execute from the designated STEP of S 3 . 3. When M1 is set from OFF to ON, TestSFC1 POU will pause. When S 2 is set to 1, all the executing actions and the outputs of the SFC will be cleared, and the system will run the final scan. 4. When M2 is set from OFF to ON, TestSFC1 POU will execute its actions. When S 2 is set to 1, the status and the parameters will be cleared, and the system will begin to execute from STEP 2. 5. When M3 is set from OFF to ON, TestSFC2 POU will pause. When S 2 is set to 0, all the scan.

executing actions of the SFC and the outputs will be kept, and the system will not run the final 6. When M4 is set from OFF to ON, TestSFC1 POU will execute its actions. When S 2 is set to 2, the status and the parameters will be kept and will begin to execute from where it pauses. *SFCRUN will activate SPC POU at the next scan. Main POU 6-544