Schneider Electric — Logic Input Assignment

Altivar 16 AC Drive Option card functions, logic input parameters Reduce current limit Available on: VW3A16201 + VW3A16104 . 1 logic input, either LI1, LI2 or LI3. Function Reduction of maximum current on the Altivar 16. Adjustment 0.5 to 1.5 times the continuous drive output current. Applications Machines which may frequently jam such as conveyors, grinders and extruders. Torque regulation or simple tension-controlled applications. Use with a motor that has a power less than that of the drive. +Speed/- speed Available on: VW3A16201 + VW3A16104 . Logic inputs LI1 and LI2.

Function Increase and decrease speed by using two logic inputs, with or without storing last reference (similar to a motorized potentiometer). Applications Command for a multi-drive system. f With storing of last HSP t 1 0 FW (RV) t 0 LI1 1 t 1 LI2 0 t Jog Available on: VW3A16201 and VW3A16203 , with or without VW3A16101 , VW3A16102 or VW3A16104 . 1 logic input LI1, LI2 or LI3. Function Jog function with a minimum ramp of 0.1 s and a reference speed up to 10 Hz (factory preset to 5 Hz). Minimum time betweeen two jog pulses is 0.5 s. Applications Machines which run in manual. Used to move slightly forward when performing maintenance. f t 1 0 FW (RV) t 1 23 referenc 0.5 s