omron — Camera Properties

Camera Properties Virtual Camera Object Editor Emulation Configuration Selection 2. Use the Device list to select the physical or emulated camera to associate with this vir- tual camera. If you checked the "Create a virtual camera" box when adding the camera, this step is not necessary. a. Click Device in the Configuration group. b. Click the drop-down arrow to display the available options to associate with the virtual camera. If only one camera is installed in the workspace, it will be the only camera dis- played in the list. c. Click the camera you want to associate with this virtual camera. d. Click OK. 3. Click Edit to open the Camera Properties dialog.

This is used to view information about the camera and make changes to shutter, gain, brightness, and other settings. See See "Camera Properties". 4. Click and Enable Image Logging to specify a directory and the number of images you want to save. It will delete old images as needed when that number of images is exceeded. 5. Set the Vision Display Units, if a different display scale is needed. The options are: Meter, Centimeter, Millimeter, or Micron. Millimeter is the default, and will not usu- ally need to be changed. NOTE : The Calibration for a camera can be Saved, and then Loaded into another workspace, if desired.

Related Topics Adding Vision Tools Calibration Overview Camera Properties Use the Camera Properties window to get information about your camera and set various parameters to control the camera's behavior. ACEUser's Guide, 3.6.x, 18316-000 Rev A Page 335