omron — Locator

Locator Results ACEUser's Guide, 3.6.x, 18316-000 Rev A Page 560 Object Definition Minimum Required Features Sets the minimum percentage of required fea- tures that must be recognized in order to consider the object instance as valid. Model Disambiguation Enabled When set to true (default), the Locator applies dis- ambiguation to discriminate between similar mod- els and between similar hypotheses of a single object. When set to false, the Locator does not apply disambiguation. Model Optimizer Enabled Specifies whether Models can be optimized inter- actively. Nominal Rotation Specifies the range of rotation allowed for an instance to be valid.

Nominal Scale Factor Nominal Scale Factor sets the required scale factor for an object to be recognized. Output Symmetric Instances When true, all the symmetric poses of the object instances are output. When false, only the best quality of the symmetric poses of the object instance is output. Percentage Of Points To Analyze Percentage of points on the contour that will be analyzed. Positioning Level Configurable effort level of the instance pos- itioning process. Recognition Level Configurable effort level of the search process. Search Based On Outline Level Only When set to true, the Locator does not use the models at the Detail level for the positioning pro- cess.

Show Model Name When set to true, and Show Results Graphics is enabled, the model name is displayed in the Vision Window. Timeout Time (in milliseconds) after which the Locator tool aborts its search process. Object Definition Instance Index of the result instance, starting with 0.