omron — Communicating Variable Values

Communicating Variable Values The Edit OPC window is divided into two panes: the left-hand pane shows a folder tree structure, which mir- rors the tree view in the Workspace Explorer; the right-hand pane shows the tab groups and data items available in each for the selected object. To expose a data item to OPC: 1. In the left-hand pane, use the tree view to locate and select the object that contains the desired data element. 2. In the right-hand pane, use the tabs to locate the desired data element. 3. Select the Expose check box to expose that element to OPC. 4.

Optionally, select the Read Only check box, if you want to make the data element read only (it can be read but cannot be written to). 5. Optionally, rename the Tag Names for the exposed elements. Note the following: l Each tag name must be unique. l Every item must have a tag name (in other words, the Tag Name field cannot be empty). Communicating Variable Values The OPC Data Access and Process Control feature can be used to communicate the values of specified V+ global and local variables. To enable this feature: 1. Install and enable the OPC Data Access and Process Control feature. For details, see Installing and 2. Create a variable for the value that you want to export.

For details, see Variable Editor on page 131. Enabling OPC on page 785. 3. Enable OPC Export for that variable. For details, see Exposing Object Data Elements on page 786. 4. In your OPC client application, create an OPC tool that reads the exported value. See your OPC client documentation for details. Variable Export Details Through the OPC server, a variable is exported to a namespace that matches the name of the variable in ACE. ACE User's Guide, 3.6.x, 18316-000 Rev A Page 787