Configuration Items To test the robot-to-belt calibration: 1. Make sure the belt is turned off (so the belt is not moving). 2. Place a part on the belt. 3. Position the robot tool tip so that it is just above the center of the part. 4. On the Test Calibration page, click Start Tracking . 5. Start the conveyor (so the belt is moving). The robot should track the target location until it leaves the tracking region. 6. When you have finished, click Stop Tracking to stop the tracking. 7. Click Next to proceed. The Robot-to-Belt Calibration wizard closes. The robot and belt conveyor are now calibrated. Configuration Items This section describes the Configuration Items group in the Process Manager.
For details, see Process Man- ager on page 843. The Configuration Items group defines the workcell items, and the relationships between those items, that are associated with a particular workcell configuration. The Configuration Items group also allows quick access to the robot position (location) editors for a particular item, such as the idle, part pick, or part place location. Creating the Configuration Items The Configuration Items are created automatically, as the workcell process is defined through the Part Pro- cess editor. As items are added/deleted in the Part Process editor, they are added/deleted in the Con- figuration Items group.
For example, a basic pick and place application would look like this in the Part Process editor: ACE User's Guide, 3.6.x 18316-000 Rev A Page 856