Sensor Calibrations Saving and Loading a Calibration After a calibration has been completed, the data can be saved by selecting File > Save To on the cal- ibration editor menu. You can load a previously-saved calibration file by selecting File > Load From on the calibration editor menu. Automated versus Manual Calibrations The calibrations can be performed using either the calibration wizard (preferred method) or the manual cal- ibration procedure. In the calibration wizard (automated process), you teach the initial locations and then the wizard automatically performs the robot movements to acquire enough data points to calibrate the sys- tem.
In the manual procedure, you have to move the robot through each step of the process until enough data points have been acquired. The manual method is provided for cases where obstructions in the work- cell do not allow for automated movement of the robot during the calibration process. NOTE: 1. Adept recommends that you use the calibration wizard (automated process), in order to obtain the optimum performance from your system. 2. The manual calibration procedure is available for the Fixed Camera and Refinement Camera cal- ibrations. Using the Calibration Wizard NOTE: This feature operates differently in emulation mode.
For details on emulation mode wizards, see Emulation Mode Wizards on page 185. The Sensor Calibration wizard provides an interactive series of steps that guide you through the calibration process. Each step of the wizard contains graphical aids and text that describe the particular step being per- formed. As each step of the wizard is completed, the information from that step is collected and used to pop- ulate the fields in the Sensor Calibration Editor, which is described in the previous section. For more details on the buttons and indicators on the wizard pages, see Wizards on page 181. Belt Camera Calibration NOTE: This feature operates differently in emulation mode.
For details on emulation mode wizards, see Emulation Mode Wizards on page 185. This section describes the Belt Camera Calibration wizard in the Process Manager, which is accessed from the Sensor Calibrations group. The Sensor Calibrations group defines the robot-to-sensor calibrations for the selected workcell process. For more details on the Sensor Calibrations group, see Sensor Calibrations on page 909. ACE User's Guide, 3.6.x 18316-000 Rev A Page 914