Cobra i-Series Pick and Place Samples Cobra i-Series Pick and Place Samples After you select the application sample, you are ready for the setup and programming of the application. An interview wizard guides you through the process, as described below. The following instructions are provided as an example of a MicroV+ static pick and place application. The steps for your application sample may vary, depending on the application sample selected in the previous section. However, this example will provide an overview of the basic steps for programming an application sample. What happens next? You will use the interview wizard to: l Select the robot l Teach the process.

You will teach the Safe, Pick, and Place positions. As part of the Pick (or Place) teach process, you will select a mode for each (pick from a static position, or pick from a pallet). The interview wizard will pause momentarily to create the objects and write the program code, then you will: l Enable the signal numbers defined in the generated code. l Run the process using the Task Manager panel of the Controller Development Tools window. To program the application: After you select the application sample, the first page of the interview wizard opens. If you already have a Cobra i-Series robot in your workspace, you will see the following screen.

ACE User's Guide, 3.6.x, 18316-000 Rev A Page 953