COOLING SYSTEM Tests and Adjustments 12/05 TESTS AND ADJUSTMENTS Filler Cap 1. Connect the cap to the cooling system tester using the adapter for the cap. Pressure Test Cooling System and Filler Cap Figure 7-3 2. Pump until the cap opens (Figure 7-3) . Cooling System Use a cooling system tester with connections compatible with the Yanmar BY2 series cooling system. 1. Remove the filler cap from the heat exchanger. WARNING! Burn Hazard. NEVER remove the coolant filler cap if the engine is hot. Steam and hot engine coolant will escape and seriously burn you. Allow the engine to cool before attempting to remove the filler cap. 2.
Check that the lugs and sealing flange on the filler pipe are undamaged and free from anything that might prevent a good seal. 3. Install the tester and adapter in place of the filler cap. 4. Pump until pressure is 1.45 bar (21 psi) (Figure 7-2) . Figure 7-3 Figure 7-2 3. The tester needle should stop at approximately 1.45 bar (21 psi). Figure 7-2 0003702 5. Pressure should hold steady. If the pressure drops, there is leakage in the system. Start by checking all hoses and pipe connections. © 2009 Yanmar Marine International BY Service Manual 7-7