COOLING SYSTEM Repair Seawater Pump 6. Inspect the housing and cover for excessive wear. Inspect and Replace Impeller 1. Drain the seawater circuit by loosening the drain cock (Figure 7-24, (1)) in the outlet pipe. Note: When installing the new impeller, rotate the impeller clockwise to bend the vanes in the direction of rotation (Figure 7-26) . Figure 7-24 Figure 7-26 (1) (1) 0003655 Figure 7-24 2. Remove the seawater pump belt. See Replace Seawater Pump Belt on page 7-19. 3. Remove four screws and remove the water pump cover, belt pulley and shaft as an assembly (Figure 7-25, (1)) . Figure 7-25 Figure 7-26 0003658 (2) 7.
Install a new O-ring (Figure 7-26, (1)) and hold it in the groove using petroleum jelly. 8. Install the shaft, cover and pulley assembly. Install and tighten four screws. 9. Install the seawater pump belt. See Replace Seawater Pump Belt on page 7-19. (1) 0003657 Figure 7-25 4. Remove the impeller (Figure 7-25, (2)) from the housing. 5. Inspect the impeller for cracks, broken vanes, or excessive wear. Replace as necessary. 7-18 BY Service Manual © 2009 Yanmar Marine International