ELECTRICAL AND ECU Component Tests Figure 12-15 P0183 - No connection / short to ground Test Values Resistance at -20°C (-4°F): 20 to 24 k-ohm 0004172 Resistance at 0°C (32°F): 16.5 to 8 k-ohm Figure 12-15 Resistance at 20°C (68°F): 2.4 to 3.2 k-ohm 1 – Pin 1 - Glow plug No. 1 2 – Pin 2 - Glow plug No. 2 3 – Pin 3 - Glow plug No. 3 4 – Pin 4 - Glow plug No. 4 5 – Pin 5 - Glow plug No. 5 6 – Pin 6 - Glow plug No. 6 7 – Pin 12 - Signal of measured value (ECU pin 168) 8 – Pin 6 - Ground (ECU pin 170) 9 – Pin 5 - 12V (Fuse F5) Resistance at 120°C (248°F): 0.5 to 0.6 k-ohm Figure 12-16 (1) (2) 0004168 Figure 12-16 Connector X3 The control signals travel via connector X3.
If the glow control unit is not installed, connector X3 must be protected by a cover. 1 – Pin 1 - Ground (ECU pin 111) 2 – Pin 2 - Out (ECU pin 183) Fuel Volume Regulator Fuel Temperature Sensor This component controls fuel volume in the fuel injection system. The ECU uses values supplied by several sensors and sends corresponding signals to control fuel pressure. It is mounted on the rear of the high-pressure fuel pump. This sensor measures the temperature of the fuel being supplied to the high-pressure fuel pump. It is an NTC (negative temperature coefficient) type sensor. It is mounted in the fuel line just upstream from the high-pressure fuel pump.
Results of Failed Regulator Failure of the regulator results in: The sensor output is used by the ECU for: Limitation of the injection rate ( See Engine Faults and Torque Limitations on page 13-3. ) Protecting the engine from overheating Calculation of the injection rate All high-pressure fuel system control is provided by the fuel rail pressure control valve. Calculation of the rate of the fuel pump Results of Failed Sensor NOTICE: If a fault code is generated, check the fuel supply and delivery first. Failure of the sensor results in: Limitation of the injection rate ( See Engine Faults and Torque Limitations on page 13-3.
) If this regulator is defective, the following P-codes may be generated: P0001 - not connected Destruction of the sensor if short circuit to B+ P0003 - short circuit to ground If this sensor is defective, the following P-codes may be generated: P0004 - short circuit to B+ P0182 - short circuit to B+ P0088 - fuel rail pressure out of range 12-18 BY Service Manual © 2009 Yanmar Marine International