Yanmar — Diagnostic Trouble Codes

TROUBLESHOOTING Trouble Codes TROUBLE CODES Working Procedure Try to form a comprehensive view of the problem. Start by asking the operator the following: Symptoms Conditions in which the fault occurs How often the fault occurs If the trouble codes have been erased Then, extract all the stored trouble codes. Compare them and try to conclude the probable cause of the fault before taking any other measures. The trouble codes are stored in the order they were registered. Diagnostic Trouble Codes Some conditions will produce an alarm but do not generate a trouble code. An example is engine overheat (over 108°C [226°F]) caused by an obstructed seawater inlet.

The overheat alarm will sound and the engine torque will be reduced to protect the engine, but no code will be set. Conditions that set a trouble code are generally caused by a sensor or other component sending an out-of-normal range signal to the ECU. An example is a disconnected intake air pressure sensor which would set a P0237 code.

13-10 BY Service Manual © 2009 Yanmar Marine International Code Part or System Mode Run Or Conditi on Engine Can Start Check Engine Alarm No Code Coolant Temp Under 0°C (32°F) 1000 rpm yes no No Code Coolant Temp Over 108°C (226°F) reduce yes no No Code Coolant Temp Over 110°C (230°F) reduce yes alarm No Code Charge Air Temp Over 110°C (230°F) reduce yes no No Code Boost Pressure Reading 4BY2 - over 1.9 bar (27.5 psi) (relative*) or 2.9 bar (42.0 psi) (absolute**) 6BY2 - over 2.3 bar (33.3 psi) (relative*) or 3.3 bar (42.9 psi) (absolute) reduce yes alarm No Code Fuel Temperature Over 90°C (194°F) reduce yes no No Code Neutral Switch Only in case of analog throttle or in case of CAN-fault (U0001), wrong configuration - neutral position no no alarm P0001 Fuel Metering Unit Not connected reduce yes alarm P0003 Fuel Metering Unit Short circuit to Ground no no alarm P0004 Fuel Metering Unit Short circuit to B+ reduce yes alarm P0087 Rail Pressure Governor Deviation Fuel rail pressure out of range reduce or shut off depends on fault alarm