Komatsu — 3.4.2 OPERATING THE ELECTRONIC MONITORING SYSTEM

OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Basic Display The basic display in system level -0- is for general information during operation and shows the Date, the Time of Day, the Oper- ating Hours (h) and the speed of engine 1 (M1) and engine 2 (M2). Within Level -0- further operating data can be called up by pressing key (12). Call up further Operating Data in System Level -0-: The following data can be called up by pressing key (12), illust. Z25237 The maximum permissible temperature of the PTO gear oil and of the hydraulic oil depends on the viscosity of the oil used. The following table shows the maximum permissible temperature of the respective oil viscosity.

PTO Gear Oil Hydraulic Oil *1) Temperature value for new oil (freshly filled in). *2) Temperature value for used oil. This temperature value has to be adjusted when the vis- cosity of the hydraulic oil has decreased by 10 to 12 percent compared with new oil. The determination of the hydraulic oil viscosity should be carried out in the course of the regular oil analysis procedure. The input (setting) of the viscosity class has to be done in main group Service *SETTINGS*. For more information refer to page 135. 103 -0- PTO Gear oil temperature M1 Nominal Actual: °C -0- PTO Gear oil temperature M2 Nominal Actual: °C -0- Hydraulic oil temperature Nominal Actual: °C Fuel level :

% -0- Boardnet voltage Nominal >22 V Actual: V Charging current Nominal 4-100 A Actual: A -0- Ambient temperature : °C REMARK Viscosity class according to ISO T 32 CLP 150 maximum permissible temperature °C: Viscosity class according to ISO VG 22 VG 32 VG 46 VG 68 VG 100 SHELL SL0851 maximum permissible temperature °C: