ELECTRICAL SYSTEM 2.3 Inspecting and repairing starter 2.3.1 Inspecting brushes for wear Measure the length of the brushes. If the measured value is less than the limit, replace both the brush holder assembly and the brush assembly with new ones. Measure the length of the brush. Replace if the length is equal to or less than the limit. Inspecting brushes for wear 2.3.2 Measuring brush spring load Using a new brush, measure the spring load at which the spring lifts from the brush. If the measured value is less than the limit, replace the spring with a new one.
Measuring brush spring load 2.3.3 Inspecting brush holder for insulation Check for no continuity between each brush holder and the brush holder base. If continuity is found, replace the brush holder assembly. Check the brush holders for looseness. Insulated brush holder Brush holder base Checking brush holder for grounding 2.3.4 Measuring commutator radial runout (1) Inspect the commutator surface. If the surface is rough, polish it using a 400 to 600 grit sandpaper. (2) Measure the commutator radial runout with a dial gauge. If the measured value exceeds the limit, replace the armature with a new one.
Commutator 12-12 Measuring commutator radial runout Item Standard Limit Brush length 18 mm [0.71 in.] 11 mm [0.43 in.] Item Standard Limit Brush spring load 29.4 to 39.4 N {3.0 to 4.0 kgf} [6.6 to 8.8 lbf] 13.7 N {1.4 kgf} [3.1 lbf] Item Standard Limit Commutator runout 0.05 mm [0.0020 in.] or less 0.10 mm [0.0039 in.]