Hyundai Construction Equipment — 3.3 Measuring cam lift

INSPECTION AND REPAIR OF BASIC ENGINE 3. Inspecting and repairing timing gear and camshaft 3.1 Measuring timing gear backlash Measure the backlash of the timing gears by using one of the following two methods; measure the gear play with the dial gauge plunger applied to a tooth flank on the pitch circle at a right angle to the tooth axis, or measure the clearance between gears by inserting a feeler gauge between the gears at the tooth-to-tooth contacting area. Replace the faulty gear pair if the limit is exceeded. Note: With the injection pump gear attached to the pump, install the injection pump gear to the front plate.

Measuring timing gear backlash 3.2 Measuring idler gear and camshaft gear end play Using a feeler gauge or dial gauge, measure the end play of idler gear and camshaft gear. If the measured value exceeds the limit, replace the thrust plate with a new one. Measuring idler gear and camshaft gear end play 3.3 Measuring cam lift Measure the minor and major axes of cam to determine cam lobe lift. If the lift is less than the limit, replace the camshaft with a new one.

Measuring locations D 1 D 2 Measuring directions Measuring cam lift 6-11 Item Standard Limit Timing gear backlash 0.05 to 0.15 mm [0.0020 to 0.0059 in.] 0.25 mm [0.0098 in.] Item Standard Limit End play Idler gear 0.05 to 0.20 mm [0.0020 to 0.0079 in.] 0.35 mm [0.0138 in.] Camshaft 0.10 to 0.25 mm [0.0039 to 0.0098 in.] 0.30 mm [0.0118 in.] Item Nominal Standard Limit Cam lift Inlet 6.682 mm [0.2631 in.] 6.382 to 6.782 mm [0.2513 to 0.2670 in.] 6.182 mm [0.2434 in.] Exhaust 6.722 mm [0.2646 in.] 6.422 to 6.822 mm [0.2528 to 0.2686 in.] 6.222 mm [0.2450 in.]