ZF — Shop Manual: ZF Transmission — Repair, Clutch & Gear Schematics (EN)

TRANSMISSION Ch 2 page 228 Mount two eye bolts and by means of a lifting tackle install the duct plate (1) until contact, so that the bayonet locking of wiring harness – shifting block I wiring harness - shifting block II, as well as the lockings of differential lock solenoid valve and speed sensor can be closed. Figure 737 Mount two adjusting screws and install the duct plate (1) to the transmission housing until contact. (S) Adjusting screws 120702-00082 Figure 738 Fasten the bolted connection duct plate/transmission housing (2) with torx screws (1) evenly. Tightening torque (M8/10.9x35) MA = 23 Nm (S) Socket wrench TX-40 MX504254 Install the control unit ErgoControl II (2) until contact.

Figure 739 Fasten the bolted connection control unit/duct plate (1) with torx screws evenly. Tightening torque (M6/10.9x25) MA = 9.5 Nm (S) Socket wrench TX-27 MX504253 Close lockings of the wiring harness (2) (bayonet locking and plug). By means of cylindrical screws fasten wiring harness (2) with clip (3) on the transmission housing. Tightening torque (M8/8.8x16) MA = 23 Nm Figure 740 SHOP MANUAL NOTE